C-Section vs Top-Hat Steel Buildings

The real differences in steelwork, connections and price — explained clearly

What is the difference between C-section and top-hat systems?

The important point is what steel each supplier actually uses. A building marketed as a “top-hat system” may still have C-section columns and rafters; the top-hat profiles may be the roof purlins or wall rails. InClad uses cold-rolled C-section portal frames with cleated secondary steelwork specified for the building.

Neither section name makes a complete building automatically stronger. Compare member size and thickness, steel grade, spacing, connections, bracing, wind and snow design, and what the quotation includes.

Quick comparison: InClad versus a top-hat-supported alternative

Compare the complete specification, not the headline price.
What to compareInClad C-section systemTop-hat-supported system (varies by supplier)
Primary frameCold-rolled C-section columns and rafters, selected for the building.May also use C-section columns and rafters. Confirm the actual primary frame.
Roof purlins and wall railsTypical cleated, cold-rolled C-section secondary members; layout is project-specific.Folded top-hat profiles may be used as purlins or rails. Ask for depth, thickness, spacing and grade.
Connections and assemblyPre-punched member details and manufactured bolted cleats where specified.Fixing arrangements vary; some use self-drilling screws. Ask for joint details and capacities.
Roof and wall build-upSingle-skin, built-up twin-skin or composite options, with roof and walls specified separately.Can offer similar options. Compare the exact panels, insulation, flashings and inclusions.
Openings and usable spaceShutters, PA doors, openings and bespoke bay geometry can be designed into the frame.Compare clear openings, internal dimensions, framing around doors and any additional posts.
Strength and stabilitySection sizes, bracing, restraint and connections must be checked against the project’s loads.Exactly the same requirement. No section profile alone proves one complete building stronger.
Total quotationCheck what is included: frame, cladding, fasteners, documents, delivery and fitting.Check the same items plus doors, gutters, offloading, HIAB, calculations and VAT.

Why might InClad cost more? Pre-punched frame components, manufactured cleats, bolted connections and bespoke detailing form part of the system. A cheaper quotation may be perfectly suitable, but only compare it after checking the frame specification, what is included and the engineering evidence.

Jump to the 20-point buyer checklist · Read our technical specification · See completed projects · Request a like-for-like quote

For independent background on the role of roof purlins and wall rails, see SteelConstruction.info’s building-envelope guidance. This is general engineering information, not a product endorsement.

How to identify the photographs below
INCLAD — OUR C-SECTION SYSTEMCOMPARISON — REFERENCE IMAGES

Every photo group is labelled, including when viewed one after the other on a mobile. Reference photographs illustrate different details; they are not attributed to a named competitor.

InClad: C-section structural frame

  • Cold-rolled C-section columns and rafters form the primary structural frame
  • Factory-prepared components and engineered bolted haunch, cleat and connection details
  • Secondary members and connections specified to suit the building design
  • Any structural calculations, foundation reactions and drawing package are identified in the project quotation
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Top-hat approach: confirm the primary frame

A building described as a top-hat system may still have C-section columns and rafters. The top-hat sections may be the roof purlins or wall rails supporting the cladding.

  • Identify the main frame and the secondary supports separately
  • Check the section profile, steel grade, thickness and spacing of each
  • Compare the complete connection and bracing arrangement
  • A section name alone does not establish the strength or suitability of a building
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Purlin System

InClad: cleated roof purlins

  • Our typical C-section roof purlins are arranged in line with the main rafters where the design allows
  • Factory-prepared connections use engineered cleats and specified bolts
  • Support spacing and restraint are selected for the cladding and loading, not assumed from a standard kit
  • Check the issued connection drawings for the precise arrangement
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Top-hat approach: roof purlin design

Top-hat purlins can form part of a properly engineered cold-rolled steel building. The comparison is about the full support system, not whether the profile has a particular name.

  • Ask for purlin depth, gauge, material grade and spacing
  • Confirm screw or bolted fixing details, cladding restraint and wind suction checks
  • Compare the connection drawings, not a photograph alone
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Uprights and Rafters

InClad: C-section columns and rafters

  • C-section uprights and rafters sized by calculation
  • Sections selected for your span, eaves height and loading
  • Deflection checked as part of the design
  • Designed for long-term performance
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: compare the actual main frame

Buildings described as top-hat systems can also use C-section columns and rafters.

  • Compare the primary sections’ sizes, grades and thicknesses
  • Check bay spacing, clear span and any intermediate supports
  • Ask for the stated load assumptions and deflection limits
  • Do not infer frame strength from the roof purlin profile alone
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Eaves Haunch Connections

InClad: bolted eaves connections

  • Engineered bolted haunch connection between column and rafter
  • Designed to transfer load at a key stress point
  • Helps maintain overall frame stiffness
  • Detailed as part of our connection design
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: request the knee detail

  • Haunch connection details vary by system
  • Performance depends on the connection design
  • Ask how the column-to-rafter joint is detailed
  • Compare on calculations, not labels
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Why this matters:

A well-designed knee (haunch) connection contributes to overall frame stiffness and helps doors and openings stay aligned over time.

Eaves System

InClad: eaves and weathering

  • Roof-edge flashings and gutter details can be designed around the selected roof and wall cladding
  • Weathering, closures and seals are specified for the agreed cladding build-up
  • Gutters and downpipes are optional unless the quotation expressly includes them
  • Custom flashings and gutters can be manufactured to the project details
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: compare the eaves details

  • Eaves detailing varies by manufacturer
  • Check how gutters and flashings are integrated
  • Weather sealing depends on the detail used
  • Ask for drawings of the eaves detail
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Apex / Ridge Connections

InClad: bolted apex connection

  • Engineered bolted ridge (apex) connection
  • Structural continuity across the roof span
  • Designed to distribute roof loads
  • Detailed as part of our connection design
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: request the apex detail

  • Apex connection details vary by system
  • Performance depends on the design used
  • Ask how the ridge joint is detailed
  • Compare on calculations
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Cleat Connections

InClad: manufactured bolted cleats

A cleat is the manufactured bracket connecting one steel member to another. InClad uses pre-punched holes and specified bolted connections so the intended fixing positions are set out before the kit is delivered.

  • Bolts, hole sizes, cleat dimensions and member thicknesses are confirmed on the issued drawings for that building
  • Purlin-to-cleat and cleat-to-frame fixing arrangements are selected for the connection forces
  • The load capacity depends on the whole joint: bolt grade, edge distances, cleat, section thickness and the engineered design
  • Do not compare a screw and a structural bolt solely by their diameters
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: compare every fixing detail

Some top-hat support systems use self-drilling screws instead of the bolted cleat arrangement shown alongside. Suppliers use different details, so establish exactly what is being quoted.

  • Ask for the fixing type, diameter, grade and number at each connection
  • Check the thickness of the metal into which a screw fixes
  • Ask how pull-out, pull-over, bearing and shear are checked where relevant
  • Compare complete tested or calculated connections, not the nominal size of one fixing

Buyer check: A reference to a 5.5 mm screw and one to an M16 bolt describe different fasteners, not a verified strength ratio. Request the actual supplier connection detail.

COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Base Cleat System

InClad: designed base connections

  • Baseplates or base cleats provide a designed connection between columns and foundations
  • Anchor specification and reactions depend on the frame and site conditions
  • Foundation design and existing slab suitability must be checked separately where required
  • Drawings and foundation information are supplied to the scope stated in the quotation
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: foundation interface

  • Base connection details vary by system
  • Anchoring depends on the specified fixings and foundation
  • Check the base details and foundation requirements
  • Compare on calculations
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Purlin Stays

InClad: specified purlin restraint

  • Purlin restraints, ties and stays are specified where the structural design requires them
  • The restraint layout contributes to member stability and is not interchangeable between buildings
  • Never omit or move restraints without confirmation from the design engineer
  • Compare the actual component and fixing schedule
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: confirm restraint components

  • Purlin restraint varies by system
  • Check what restraint is included
  • Performance depends on the design
  • Compare on calculations
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Door System

InClad: framed door openings

  • Roller shutters, personnel doors and other openings can be set out as part of the frame design
  • Additional framing is detailed where the opening and loading require it
  • Check clear opening sizes, shutter headroom and side clearances
  • Doors and shutters are supplied only when specifically included in the quotation
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: check door-opening supports

  • Door framing varies by manufacturer
  • Check how openings are framed and supported
  • Alignment over time depends on the design
  • Ask for the opening details
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Bracing System

InClad: structural bracing

  • Engineered bracing and restraint address lateral stability and project-specific wind loading
  • Ties, bracing members and fixings are set out for the agreed building arrangement
  • Open sides, wide doors or frame-only configurations must be reviewed as part of the design
  • Removing braces or rails after design can affect stability
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: request the bracing layout

  • Bracing arrangement varies by system
  • Lateral stability depends on the bracing design
  • Check what bracing is included
  • Compare on calculations
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Cladding Buildup

InClad: roof and wall cladding options

  • Roof and wall systems can be specified independently
  • Single-skin sheeting, insulated built-up twin-skin and composite panels are available subject to the project
  • Insulation, condensation management and weathering details depend on intended use
  • Compare sheet gauges, panel specifications, flashings and optional extras separately
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: compare the exact build-up

  • Cladding options vary by supplier
  • Insulation performance depends on the product specified
  • Check the cladding specification and finish
  • Compare like for like
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Sway and Stability

InClad: engineered frame stability

  • Frame designed to control lateral movement
  • Stiffness checked as part of the design
  • Engineered connections and bracing work together
  • Designed for long-term stability
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: check lateral movement

Top-hat roof or wall supports do not, by themselves, establish how much the complete building will sway.

  • Ask how lateral stability is provided through the frame, connections and bracing
  • Confirm the calculations use your site wind and snow loads
  • Check whether any cladding contribution to stability has been assumed
  • Compare the full structural design rather than one steel profile
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

In simple terms:

Every steel building needs a stable structural system – a combination of frame sections, connections and bracing. Our C-section frames are engineered as a complete system, including bracing, for your site and loading.

Load Capacity

InClad: project-specific design loads

  • Frame members and connections are selected for the project rather than a blanket maximum span claim
  • Wind, snow, use and any additional loads should be established before manufacture
  • Larger spans, greater eaves height or open bays may need additional supports or a different structural solution
  • Check what calculations and structural documents are included in the agreed quotation

Alternative: compare design loads

  • Load capacity varies by system and design
  • Check the design loads used
  • Suitability depends on the specification
  • Compare on calculations

Compliance

InClad: applicable production controls

  • Applicable structural components are manufactured under InClad’s stated BS EN 1090-1 Factory Production Control system
  • The relevant certification scope and supporting documents can be requested
  • Building Regulations compliance is project-specific, and calculations or approval services are not automatically included in every supply-only price
  • Read our certification and compliance information

Alternative: verify its documentation

  • Compliance depends on the manufacturer and design
  • Ask for calculations and conformity documentation
  • Check certification for the components supplied
  • Compare documentation like for like

Durability

InClad: coated frame and cladding

  • Galvanised or painted frames for corrosion resistance
  • Coated cladding panels for long-term durability
  • Low routine maintenance
  • Designed to last
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM

Alternative: coating and service life

  • Lifespan depends on the materials and coatings used
  • Varies by manufacturer and specification
  • Check the frame and cladding coatings
  • Compare maintenance requirements
COMPARISON / REFERENCEALTERNATIVE DETAIL TO COMPARE

Bespoke Geometry — Designed Around the Building You Need

A steel building does not have to be a standard rectangle. Where the engineering allows it, the frame can be designed around the site, access, intended use and openings rather than forcing the project into a fixed catalogue size.

  • Tapered and unequal bays where the footprint or access requires them.
  • Offset ridge and mono-pitch roofs where a conventional central apex is not the best solution.
  • Different eaves heights and stepped arrangements where the building needs to respond to the site or adjoining structures.
  • Larger or open bays with additional support designed into the column-and-rafter arrangement where required.
  • Roller shutters, PA doors, windows and openings positioned as part of the frame design instead of being treated as an afterthought.
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM
Steel storage building under construction with cold-rolled frame and wall cladding

Designed to Assemble — Not Measured Into Position

The kit is prepared so the structural layout is defined before it reaches site. Pre-punched holes, manufactured cleats and bolted connections reduce the amount of setting-out that has to be improvised during erection.

  • Predetermined fixing positions: the installer is assembling designed connection points rather than choosing rail positions from scratch.
  • Bolted secondary steelwork: purlins and rails connect through manufactured cleats instead of relying on repeated on-site screw positioning alone.
  • Consistent bay-to-bay geometry: the connection positions help keep the frame and cladding support lines repeatable.
  • Clearer DIY/supply-only erection: the issued drawings and assembly information show where the main components belong.
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM
InClad cold-rolled steel building structure under construction

More Efficient Use of the Frame Depth

On our typical twin-skin arrangements, secondary steelwork can sit within the depth of the main C-section frame rather than creating another layer outside it. That can be particularly useful on smaller insulated buildings where every millimetre of internal width and headroom matters.

  • Wall rails between the main uprights can reduce unnecessary build-up outside the primary frame line.
  • Roof purlins between the rafters can use the structural depth more efficiently.
  • Cleaner internal lines make it easier to understand where the finished internal face will sit.
  • The exact finished dimensions still depend on the chosen cladding and insulation system, so the issued project drawings always take priority.
INCLAD STEEL BUILDINGSOUR C-SECTION SYSTEM
Steel storage building under construction with cold-rolled frame and wall cladding

20 Things to Check Before Choosing a Steel Building

Use this checklist alongside the construction photographs above. The aim is to understand what each quotation includes and why a specification differs, not to assume that every supplier uses the same design.

Frame and connections

  1. Main frame and secondary steelwork. Identify the columns and rafters separately from the roof purlins and wall rails. A top-hat support system may still use C-section main frames.
  2. Span, eaves height and usable space. Match the width, length and eaves height. Check whether internal posts, braces or door gear reduce the space you can actually use.
  3. Steel specification. Compare member depth, profile, material grade and thickness together. Steel thickness alone does not establish the capacity of a complete frame.
  4. Frame and purlin spacing. Check bay centres and the distance between cladding supports. Two buildings with the same footprint can have different support layouts.
  5. Connections and fixings. Ask for the cleat and joint details, bolt or screw specification, quantity and supported metal thickness. Compare complete connections rather than fastener diameter alone.

Site, openings and future use

  1. Wind and snow design. Provide the actual site location and intended building use. Confirm the design basis rather than relying on an unspecified standard loading.
  2. Bracing and open sides. Ask how the quoted frame-only, open-gable or open-bay arrangement is stabilised. Do not assume bracing, rails or cladding can be removed from a closed-building design.
  3. Clear door openings. Compare usable opening width and height, not just the frame opening. Confirm shutter operation, headroom, side clearance and whether the door itself is included.
  4. Foundations and anchors. Establish who supplies the foundation design, reactions and anchor specification. Do not assume an existing concrete slab is suitable without assessment.
  5. Future additions. Mention solar panels, ceilings, suspended equipment, mezzanines or extensions before ordering. Extra loads and later alterations need a design review.

Cladding, comfort and durability

  1. Roof and wall systems. Distinguish single-skin sheeting from a built-up twin-skin insulated system and factory-made composite insulated panels. Specify the roof and walls separately.
  2. Condensation control. Anti-condensation fleece helps manage drips on single-skin roofing; it is not a substitute for insulation. Ventilation and drying conditions still matter.
  3. Insulation performance. Compare the exact panel or build-up, insulation thickness and declared thermal performance. A 40 mm composite option is not automatically suitable for every heated building.
  4. Coatings and maintenance. Check the frame coating, cladding finish and suitability for the environment. Ask for maintenance instructions and the terms of any applicable warranty.
  5. Weathering details. Compare flashings, ridge and eaves details, closures, seals, gutters and downpipes. Confirm which items are included, optional or supplied by others.

Kit, service and total price

  1. Bespoke geometry. Ask about tapered bays, different eaves heights, roof forms, lean-tos and opening positions. Confirm design feasibility rather than assuming a standard kit can be altered.
  2. Preparation for assembly. Check pre-punched holes, cut-to-length components, identification and the fixing schedule. Confirm which parts arrive prepared and what work remains on site.
  3. Drawings and support. Confirm which drawings, calculations, foundation information and applicable installation guidance are included. Identify separately priced documents before placing an order.
  4. Delivery and installation scope. Separate supply-only from supply-and-fit. Check delivery, offloading or HIAB, access equipment, travel and groundworks; none should be assumed from a headline price.
  5. A genuinely comparable total. Compare the same dimensions, site, cladding, openings and scope, with VAT and every selected extra shown consistently. Keep optional items separate from the included package.

Comparing two quotations? Send InClad the same dimensions, site postcode, intended use and specification so the scope can be checked consistently. Remove personal or confidential details from any third-party documents before sharing them.

Request a project-specific quotation or read our steel building technical specification.

Compare the Specification. Choose with Confidence.

Tell us your building size, site postcode and intended use. Request a quotation with the frame, cladding, openings and supply or installation scope clearly defined.